Detail RTD – TC THERMOMETERSPt100 AND TC INPUT, Merk : DeltaOhm

The HD2178.1 and HD2178.2 are portable instruments with a large LCD display. They measure the temperature using immersion, penetration air or contact probes with RTD or thermocouple sensor. A 3 or 4 wire Pt100 sensor or a 2 wire Pt100 sensor can be connected to the input B, while a thermocouple of type K, J, T, E, N to the input A.The probes for input B, 8 poli DIN45326 connector, are equipped with automatic detection module with the factory calibration settings already being memorized inside. A miniature polarized connector for thermocouple is provided for input A. The instrument HD2178.2 is a datalogger which stores up to 80,000 samples. These data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be confi gured using the menu.The models HD2178.1 and HD2178.2 are fi tted with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer.The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be disabled. The instruments have IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions (Length x Width x Height) 185x90x40mm Weight 470g (complete with batteries) Materials ABS, rubber Display 2x41D2 digits plus symbols Visible area: 52x42mm Operating conditions Operating temperature -5…50°C Warehouse temperature -25…65°C Working relative humidity 0…90%RH without condensation Protection degree IP67 Power Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼A Mains Output mains adapter 9Vdc / 250mA Measuring unit °C - °F Security of memorized data Unlimited, independent of battery charge conditions Time Date and time Schedule in real time Accuracy 1min/month max departure Measured values storage – model HD2178.2 Type 2000 pages containing 40 samples each Quantity Total of 80,000 samples Storage interval 1s…3600s (1hour) Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/Xoff Serial cable length Max 15m Immediate print interval 1s…3600s (1hour) USB interface - model HD2178.2 Type 1.1 - 2.0 electrically isolated Connections Input for probes 8 pole male DIN45326 connector Serial interface and USB 8-pole MiniDin connector Mains adapter 2-pole connector (positive at centre) Measurement of temperature by Instrument – RTD sensors Pt100 measurement range -200 … +650°C Pt1000 measurement range -200 … +650°C Resolution 0.1°C Accuracy ±0.05°C Drift after 1 year 0.1°C/year Measurement of temperature by Instrument - Tc TC measurement range: K -200 … +1370°C TC measurement range: J -100 … +750°C TC measurement range: T -200 … +400°C TC measurement range: N -200 … +1300°C TC measurement range: E -200 … +750°C Resolution 0.1°C Instrument accuracy Thermocouple K ±0.1°C up to 600°C ±0.2°C over 600°C Thermocouple J ±0.1°C up to 400°C ±0.2°C over 400°C Thermocouple T ±0.1°C Thermocouple N ±0.1°C up to 600°C ±0.2°C over 600°C Thermocouple E ±0.1°C up to 300°C ±0.2°C over 300°C The accuracy only refers to the instrument. Error due to the thermocouple or to the cold junction reference sensor is not included. Temperature drift @ 20°C 0.02%/°C Drift after 1 year 0.1°C/year Accuracy of the thermocouple probes: The tolerance of a type of thermocouple corresponds to the maximum acceptable shift from the e.m.f. of any thermocouple of that type, with reference junction at 0°C. The tolerance is expressed in degrees Celsius, preceded by the sign. The percentage tolerance is given by the ratio between the tolerance expressed in degrees Celsius and the measurement junction temperature, multiplied by one hundred. The thermocouples conforming to regulations must comply with one of the following tolerance levels, the values of which are reported in the table. G I (special tolerances) G II (normal tolerances) The tolerances refer to the operating temperature expected for the thermocouple, in agreement with the thermoelements’ diameter. Common characteristics Resolution 0.1°C Temperature drift @ 20°C 0.003%/°C Common characteristics Resolution 0.1°C Temperature drift @ 20°C Pt100 0.003%/°C Pt1000 0.005%/°C ORDER CODES HD2178.1K: The kit is composed of the instrument HD2178.1, connection cable for serial output HD2110CSNM, 4 1.5V alkaline batteries, operating manual, case and DeltaLog9 software. The probes must be ordered separately. HD2178.2K: The kit is composed of the HD2108.2 datalogger, connection cable HD2101/USB, 4 1.5V alkaline batteries, operating manual, case and DeltaLog9 software. The probes must be ordered separately. HD2110CSNM: 8-pole connection cable MiniDin - Sub D 9-pole female for RS232C. HD2101/USB: Connection cable USB 2.0 connector type A - 8-pole MiniDin. DeltaLog9: Software for download and management of the data on PC using Windows 98 to XP operating systems. AF209.60: Stabilized power supply at 230Vac/9Vdc-300mA mains voltage. S’print-BT: On request, portable, serial input, 24 column thermal printer, 58mm paper width. Probes complete with SICRAM module TP472I: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 300 mm. Cable length 2 metres. TP472I.0: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 230 mm. Cable length 2 metres. TP473P.0: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length 2 metres. TP474C.0: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø 5mm. Cable length 2 metres. TP475A.0: Air probe, sensor Pt100. Stem Ø 4mm, length 230mm. Cable length 2 metres. TP472I.5: Immersion probe, sensor Pt100. Stem Ø 6mm, length 500 mm. Cable length 2 metres. TP472I.10: Immersion probe, sensor Pt100. Stem Ø 6mm, length 1,000mm. Cable length 2 metres. TP49A: Immersion probe, sensor Pt100. Stem Ø 2.7mm, length 150mm. Cable length 2 metres. Aluminium handle. TP49AC: Contact probe, sensor Pt100. Stem Ø 4 mm, length 150mm. Cable length 2 metres. Aluminium handle. TP49AP: Penetration probe, sensor Pt100. Stem Ø 2.7mm, length 150mm. Cable length 2 metres. Aluminium handle. TP875: Globe thermometer Ø 150 mm with handle, complete with SICRAM module. Cable length 2 metres. Temperature probes without SICRAM module TP47.100: Direct 4 wires Pt100 sensor immersion probe. Probe’s stem Ø 3mm, length 230mm. Connection cable 4 wires with connector, length 2 metres. TP47.1000: Pt1000 sensor immersion probe. Probe’s stem Ø 3mm, length 230mm. Connection cable 2 wires with connector, length 2 metres. TP47: Only connector for probe connection: Pt100 direct 3 and 4 wires, Pt1000 2 wires and Ni1000 2 wires Thermocouple probes The instruments can be connected to all the thermocouple probes fi tted with standard miniature connector available on our price-list.
Tampilkan Lebih Banyak