Back to Top

Hi, Guest!
  • HD 2110 Integrating Sound Level Meter – Portable Analyzer, Merk : DeltaOhm

HD 2110 Integrating Sound Level Meter – Portable Analyzer, Merk : DeltaOhm

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
57 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HD 2110 Integrating Sound Level Meter – Portable Analyzer, Merk : DeltaOhm

Technical characteristics Standards : Class 1 group X according to IEC 61672:2002 and class 1 according to IEC 60651:2001 and IEC 60804:2000 Class 0 according to IEC 61260:1995 Type 1 according to ANSI S1.4-1983 and S1.43-1997 Class 1-D, order 3, Extended range according to ANSI S1.11-1986 ½ inch Microphones : ü MK221 condenser microphone, polarized (200V), for free  eld, high stability, type WS2F according to IEC 61094-4 ü MK223 condenser microphone with coated membrane, polarized (200V), for free  eld, high stability, type WS2F according to IEC 61094-4 (combined with the HDWME950 weatherproof microphone unit) ü MK231 condenser microphone, polarized (200V), for diffuse  eld, high stability, type WS2D according to IEC 61094-4 Dynamic range : 23 dBA ÷ 143 dB Peak Linear range : 110 dB Acoustic Parameters : Spl, Leq, SEL, LEP,d, Lmax, Lmin, Lpk, Dose, Ln Frequency Weighting : Simultaneous A, C, Z (only C and Z for Lpk) Temporal Weighting : Simultaneous FAST, SLOW, IMPULSE Integration : From 1s to 99 hours with Back-Erase function Spectrum Analysis : Parallel lters in real time complying with IEC61260 class 0 speci cations. ü Octave bands from 16 Hz to 16 kHz ü Third octave bands from 16 Hz to 20 kHz ü Third octave bands from 14 Hz to 18 kHz ü Optional FFT from 7 Hz to 22 kHz with variable resolutions from 1.5 Hz to 100 Hz Average spectrum (AVR) mode, multi-spectrum analysis (MLT), maximum spectrum (MAX), and minimum spectrum (MIN) Audibility : Real-time comparison of third octave band spectrum with equal loudness curves according to ISO 266:2003 Statistical Analysis : Probability distribution and percentile level calculation from L1 to L99 Parameter: LFp, Leq, Lpk, A, C or Z weighted (only C or Z for Lpk) Sampling frequency: 8 samples/second Classication: 0.5 dB classes Event Analysis : Calculation of 5 freely programmable event parameters Calculation of octave and third octave band average spectra Calculation of statistical levels from L1 to L99 Event identication trigger with programmable threshold and duration lter External and manual trigger Reverberation Time (opt.) : Reverberation time measurement by sound source interruption and impulse response integrated Prole Data Logging : 1 prole with programmable sampling from 1/8 s to 1 hour and 5 proles with 2 samples/second Spectrum Data Logging : Programmable sampling from 0.5s to 1 hour (MLT, MAX, or MIN modes) Display : Backlit graphic display 128x64 ü 5 numerical parameters ü Prole of a selectable parameter with sampling time from 1/8 s to 1 hour ü Octave band spectrum from 16 Hz to 16 kHz ü Third octave band spectrum from 16 Hz to 20 kHz or 14 Hz to 18 kHz ü Graph of sound level probability distribution ü Graph of percentile levels from L1 to L99 ü Optional narrow band spectrum analysis (FFT) from 7Hz to 22 kHz Memory : Internal, equal to 8 MB (1 prole for 72 hours or over 46 recording days of 5 parameters + spectra per minute) External, via the HD2110MC memory card interface, using MMC or SD cards up to 2 GB Input/Output : RS232 serial and USB interfaces AC input and output (LINE) S/PDIF digital audio input and output External event identi cation trigger PC Programs : DeltaLog5: PC interface for data download, setup and sound level meter management (supplied with the sound level meter) DL5 Environment: For analyses according to the Decree of 16.03.98 DL5 Monitor: For real-time acquisition in the PC mass memory, scheduler, audio recording DL5 Building: For room acoustics evaluation in compliance with D.P.C.M. of 05.12.97 (it requires the “Reverberation Time” option) DL5 Noise Studio: modular program analysis “Worker protection”: Analysis module according to the Decree 195/2006 “Railway Traf c”: Analysis module of train noise according to the Decree of 16/03/1998 Operating conditions : Working temperature -10÷50°C, 25÷90%RH (without condensation), 65÷108kPa. Protection degree: IP64 Power supply : 4 alkaline or rechargeable NiMH type AA batteries or external 9÷12Vdc 300mA Dimensions and weight : 445x100x50 mm equipped with preampli er, 740 g (with batteries)
Tampilkan Lebih Banyak