Back to Top

Hi, Guest!
  • HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 pH, conductivity, dissolved oxygen, and temperature, Merk : DeltaOhm

HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 pH, conductivity, dissolved oxygen, and temperature, Merk : DeltaOhm

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
2 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 PH, Conductivity, Dissolved Oxygen, And Temperature, Merk : DeltaOhm

Conductivity meter alat ukur daya hantar listrik dalam air Introduction The instrument series HD2205.2, HD2206.2, HD2256.2, HD2259.2, and HD2569.2 is made up of bench top instruments for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature. They are fitted with a large backlighted LCD display. The HD2205.2 is equipped with two BNC inputs for the measurement of pH, mV, redox potential ( ORP) with pH or redox electrodes, or electrodes with separate reference, and one input for combined pH/ temperature probes fitted with SICRAM module. The HD2206.2 measures conductivity, resistivity in liquids, total disssolved solids ( TDS) , and salinity with combined 4-ring and 2-ring conductivity/ temperature probes. The conductivity probes can have a direct input or with SICRAM module. The inputs are separate. The HD2256.2 measures pH, mV, redox potential ( ORP) with pH, redox electrodes or electrodes with separate reference. Conductivity and resistivity in liquids, total dissolevd solids ( TDS) and salinity with combined 4-ring and 2-ring conductivity/ temperature probes. The conductivity probes can have a direct input or with SICRAM module. The inputs are separate. The HD2259.2 measures pH, mV, redox potential ( ORP) with pH, redox electrodes or electrodes with separate reference; the concentration of dissolved oxygen in liquids ( in mg/ l) , and saturation index ( in % ) , using SICRAM combined probes of polarographic type with two or three electrodes and integrated temperature sensor. The HD22569.2 measures pH, mV, redox potential ( ORP) with pH, redox electrodes or electrodes with separate reference; conductivity, resistivity in liquids, total dissolved solids ( TDS) and salinity with combined 4-ring and 2-ring conductivity/ temperature probes with direct input or SICRAM module; concentration of dissolved oxygen in liquids ( in mg/ l) and saturation index ( in % ) , using SICRAM combined probes of polarographic type with two or three electrodes and integrated temperature sensor. Al models are fitted with input for the measurement of temperature with Pt100 or Pt1000 immersion, penetration or contact probes. The probes are equipped with an automatic detection module, with the factory calibration settings already being memorized inside. The pH electrode calibration can be carried out on one or fi ve points and the calibration sequence can be chosen from a list of 13 buffers. • The pH electrode calibration can be carried out on one or fi ve points and the calibration sequence can be chosen from a list of 13 buffers Temperature compensation can be automatic or manual. • The conductivity probe calibration can be performed automatically with automatically detected conductivity calibration solutions: 147¼ S/ cm, 1413¼ S/ cm, 12880¼ S/ cm or 111800¼ S/ cm or manually with calibration solutions having different values. • The dissolved Oxygen probe' s quick calibration function guarantees timely correctness of the performed measurements. • Conductivity, dissolved oxygen and temperature probes fi tted with SICRAM module can store factory and calibration data inside. The instruments of the series HD22… are datalogger, they memorize up to 2, 000 samples of data: • pH, mV and temperature: HD2205.2 • conductivity or resistivity or TDS or salinity and temperature: HD2206.2 • pH or mV, conductivity or resistivity or TDS or salinity and temperature: HD2256.2, • pH or mV, concentration of dissolved oxygen or saturation index and saturation index and temperature: HD2259.2, • pH or mV, conductivity or resistivity or TDS or salinity, concentration of dissolved oxygen and temperature: HD22569.2. The data can be transferred from the instrument connected to a PC via the multistandard RS232C serial port and USB 2.0. The storing parameters can be configured using the menu. The RS232C serial port can be used to transfer the acquired measurements to a 24 column portable printer in real time ( S’ print-BT) . The instruments equipped with HD22BT ( Bluetooth) option can transfer data without any connection to a PC or printer fi tted with Bluetooth input or through Bluetooth/ RS232C converter. The software DeltaLog11 allows instrument management and configuration, and data processing on PC. The instruments have IP66 protection degree Technical characteristics of the instruments series HD22… Common technical data Instrument Dimensions ( Length x Width x Height) 265x185x70mm Weight 490g Materials ABS, rubber Display Back lighted, matrix point display. 240x64 points, visible area: 128x35mm Operating conditions Working temperature -5 … 50° C Storing temperature -25 … 65° C Working relative humidity 0 … 90% R.H. without condensate Protection degree IP66 Power Mains adapter ( cod. SWD10) 12Vdc/ 1A Auxiliary socket For supplying of electrode holder with built-in stirrer HD22.2 Security of memorized data Unlimited Time Date and hour Real time schedule with backup battery E 3.6V - ½ AA Accuracy 1min/ month max drift Measured values storing Quantity 2000 screens Storage interval 1s … 999s Calibration storage Quantity Last 8 calibrations of each physical quantity RS232C serial interface Type RS232C electrically isolated Baud rate Can be set from 1200 to 115200 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/ Xoff Length of serial cable Max 15m USB Interface Type 1.1 - 2.0 electrically isolated USB Interface optional EMC standard regulations Security EN61000-4-2, EN61010-1 level 3 Electrostatic discharge EN61000-4-2 level 3 Electric fast transients EN61000-4-4 level 3, EN61000-4-5 level 3 Voltage variations EN61000-4-11 Electromagnetic interference susceptibility IEC1000-4-3 Electromagnetic interference emission EN55020 class B HD2205.2 pH Technical characteristics HD2205.2 pH -mV - ° C - ° F measurement Measured values pH - mV - ° C - ° F Connections Input for temperature probes 8-pole male DIN45326 connector with SICRAM modulen Inputs pH/ mV j - k female BNC Inputs for SICRAM module 8-pole male DIN45326 connector pH/ temperature l a. m Serial interface DB9 connector ( 9- pole male) USB interface USB connector type B Bluetooth Optional Mains adapter 2- pole connector ( Ø 5.5mm-2.1mm) . Positive at centre. Socket for power supply of electrode 2 -pole connector ( Ø 5.5mm-2.1mm) . holder with built-in magnetic stirrer Positive at centre ( output 12Vdc/ 200mA max) . Measurement of pH by instrument Measuring range -9.999… + 19.999pH Resolution 0.01 o 0.001pH selectable from menu Accuracy ± 0.001pH ± 1digit Input impedance > 1012© Calibration error @ 25° C | Offset| > 20mV Slope > 63mV/ pH o Slope 106.5% or Senstivity < 85% Calibration points Up to 5 points from a list of 13 automatically detected buffers. Automatically detected pH standard 1.679pH - 2.000pH - 4.000pH - 4.008pH - 4.010pH solutions ( @ 25° C) 6.860pH - 6.865pH - 7.000pH - 7.413pH - 7.648pH 9.180pH - 9.210pH - 10.010pH Measurement of mV by instrument Measuring range -1999.9… + 1999.9mV Resolution 0.1mV Accuracy ± 0.1mV ± 1digit Drift after 1 year 0.5mV/ year Measurement of temperature by instrument Pt100 Measuring range -50… + 150° C Pt1000 Measuring range -50… + 150° C Resolution 0.1° C Accuracy ± 0.1° C ± 1digit Drift after 1 year 0.1° C/ year USB 8-pole male DIN 45326 Vdc
Tampilkan Lebih Banyak